The 230-system

New 230-detectors with system thinking.

The 230-system

The 230-system is a simple way to control lighting with 230VAC (on/off).
Installation of the 230-system is always done with a shared assembly. The PS-230 is the heart of the system, which, with the help of detectors, sensors, and spring-loaded buttons, controls the lighting. The connection between the PS-230 and other devices is made with a four-wire low-voltage cable.

Installing energy-efficient lighting solutions in existing locations must be cost-effective. Our 230-system is connected on the way between the electrical cabinet and the luminaire.

Smart features

The system's smart features allow you to customize the lighting to the location's use. Automatic ignition via IR detector or acoustic detector creates security, but a push-button can also be connected to allow the user to turn on the lighting themselves. The system's task then becomes to ensure extinguishing.

The 230-system is a very complete system that offers stair automation, presence detection, and both blocking or ignition via light sensor. All functions can also be combined to create unbeatable solutions.

Introduction to the 230-system

Reference object: Acoustic detection in basement corridors

Education

What can you do with the 230-system?

Technical overview of the 230-system

Presence package IR PD230
  • Best. No: 18500 | E-No: 1306073

IR detection

The PD230 is a complete system with easy installation, for presence control of lighting in smaller locations. The PD230 has a shared assembly, which means that the detector (PD231) is easily connected with a low-voltage cable and placed in the best location for detection. The IR detector PD231 is a passive infrared detector (passive IR detector) intended for presence detection.
Five detectors PD231 can be connected to a power supply module PS230.
The power supply module PS230 is specially adapted for shared assembly and intended to power the presence detector PD231. Together, they are intended for presence control of lighting in smaller locations.

The PD230 consists of:

  • IR detector PD231
    Best. No: 18501 | E-No: 1306074
  • Power supply module PS230
    Best. No: 18502 | E-No: 1301137
Presence package acoustic AD230
  • Best. No: 18509 | E-No: 1300875

Akustisk detector

The Presence package acoustic AD230 is a complete system with easy installation, for presence control of lighting in smaller locations. The AD230 has a shared assembly, which means that the detector (AD232) is easily connected with a low-voltage cable and placed in the best location for detection. The acoustic detector AD232 is intended for presence detection.

AD230 consists of:

  • Akustisk detektor AD232
    Best. No: 18507 | E-No: 1300874
  • Power supply module PS230
    Best. No: 18502 | E-No: 1301137
Presence package IR ceiling PDC230
  • Best. No: 18498 | E-No: 1301295

Ceilingdetector

The Presence package IR ceiling PDC230 is a complete system with easy installation, for presence control of lighting in smaller locations. The PDC230 has a shared assembly, which means that the ceiling detector (PDC231) is easily connected with a low-voltage cable and placed in the best location for detection in the ceiling.

PDC230 consists of:

  • Ceiling Detector PDC231
    Best. No: 18499 | E-No: 1301228
  • Power supply module PS230
    Best. No: 18502 | E-No: 1301137
IR detector PD231
  • Best. No: 18501 | E-No: 1306074
  • Connected to PS230 for presence control with IR.
  • Corner-mounted IR detector where the lens is interchangeable.
  • 40m range in 90 degrees with standard lens 80m range in 90 degrees with corridor lens.
  • Automatic ignition via detector or manual ignition via push button.
  • 2 sec- 20 min time delay after last detection.
  • Potentiometer for setting sensitivity.
  • Potentiometer for setting built-in light sensor.
Akustisk detektor AD232
  • Best. No: 18507 | E-No: 1300874
  • Connects to PS230 for presence control with sound.
  • Detects door opening via pressure change (low-frequency sound)
  • Detects audible sounds, such as speech, footsteps, key rattling, etc. (high-frequency sound).
  • Automatic ignition via detector or manual ignition via push button.
  • Adjustable sensitivity, detection range up to 50 m in diameter 2 sec-20 min time delay after last detection.
  • Function bracket for HF block and manual ignition via push button.
Power supply module PS230
  • Best. No: 18502 | E-No: 1301137
  • Power supply, logic module and power relay.
  • The system can control up to 800W LED.
  • Press buttons can be connected directly to the bus.
  • Contact breaker bracket for connection to the contact breaker.
  • Five detectors can be connected to the 12V bus.
  • It can also be connected in parallel with three boxes for controlling 3-phase.
  • There is no internal fuse in the 230-box. If there is a short circuit on the 230V side, it is the fuse in the central that trips.
  • Approved for 10A fuse.
  • Cable length (bus cable) up to 300 meters EKKX 4x0.25.

800W
———
12W

≈ 67 Fixtures

288A
———
11,5A

≈ 67 Fixtures

Incandescent/halogen:2300W (cos φ=1)
Fluorescent tubes:1150 (cos φ=0,5)
LED:800W
Compact fluorescent tubes:800W
Starting current:max 288A
Light sensor LS233
  • Best. No: 18503 | E-No: 1300849
  • Connected to PS230 for start-up blocking.
  • For indoor environment.
  • Used primarily for start-up blocking.
  • Mode-bracket: Start block.
  • Setting range 0.5 – 10,000 Lux.
  • Switching delay 0-20 min.
Light sensor LS233UH
  • Connected to PS230 for the twilight relay function.
  • Used primarily as a twilight relay.
  • Mode-bracket: Twilight.
  • For LS233 UH to work as a twilight relay, there is also a switching delay of 0-20 min.
  • LS233 UH can work as a twilight relay both standalone against the PS230 box or together with detectors.
  • The card is mounted in an IP-65 rated box. For outdoor use.
  • Setting range 0.5 – 10,000 Lux.
Ceiling Detector PDC231
  • Best. No: 18499 | E-No: 1301228

In addition to the properties of PD231:

  • Connected to PS230 for presence control with IR.
  • Ceiling-mounted IR detector.
  • Detection range 7 m diameter at a mounting height of 2.4 m.

Product of the year for ROT work?

Energy-efficient lighting solutions, a new system that can easily turn on and off normal 230V fixtures. Now we can offer solutions for controlling lighting and saving energy even with existing fixtures.
Perfect for future ROT work in smaller spaces. (Swedish)